Visual Flame Console Vented Room Heater w/Blower RH50B

Empire Visual Flame Console Vented Room Heater with blower, 50,000 BTU, natural gas or propane RH50B
Manufacturer part number: RH50B
Manufacturer: Empire Comfort Systems
$1,799.00

Empire Visual Flame Console Vented Room Heater with Blower, RH50B

Heating large areas is economical with Empire's vented room heaters.  With their efficient heat flow the durable RH50B offers ample warmth that makes any room comfortable.  The one piece glass enclosure on the RH-50B allows you to see the flames as it heats while the optional ceramic logs add a fire like glow. 

Radiant and convection heat circulates the warmth while the blower places warm air at floor level to give "barefoot" comfort throughout the winter season.  The hydraulic thermostat needs no outside electricity assuring reliable, round-the-clock comfort.  Each unit can be installed easily by any wall with access to a vent.

  • RH-50B:  Has visual window that allow you to see flames.
  • Total comfort for a fraction of the cost of electric heat
  • Heats without electricity
  • Round outlet draft diverter rotates to either horizontal or vertical position
  • Open design allows maximum flow of heat
  • Matchless piezo ignition
  • Cabinet color:  Tan
  • 50,000 BTU input
  • Dimensions: 34" W x 16" D x 29-9/16" H, Depth including diverter: 23-3/16"
  • 124 lbs shipping weight
  • Hydraulic thermostat temperature control
  • Accessories (not included):
  • Blower kit:  Included on RH-50B
  • Output, 100 cu. ft./min.
  • Metal floor pad (36' x 21")
  • Radiant Package:  RAD8 (Eight ceramic radiants can be installed for a radiant red-orange glow)
  • Ceramic Log:  RHL2 (Add the beauty and ambiance of a real wood fire)
  • Minimum clearances to combustion from:
  • Top:  55"
  • Each side:  6"
  • Opposite side (for accessibility):  18"
  • Bottom of unit to floor covering:  0"
  • Draft diverter to wall:  2"
  • Gas inlet:
  • LP or Natural gas
  • Iron pipe size(N.P.T.):  1/2"
  • Wall to valve inlet:  8-1/16"
  • Floor covering to valve inlet:  4-1/2"
  • Center of heater to valve inlet:  Left 6-13/16"
  • Venting:
  • Size flue collar (Vertical or Horizontal):  5"
  • Floor to collar on draft diverter in vertical position:  27-3/16"
  • Floor to center of collar on draft diverter in horizontal position:  22-9/16"

Safety Control:  Pilot and main burners include automatic shutoff on all vented room heaters.

Warranty:  Combustion chamber carries a 10-year limited warranty.  All other parts carry a 1-year limited warranty.

Free Shipping within the Contiguous 48 United States

 

"WARNING" California Proposition 65

 

Customers who bought this item also bought

Empire Log Set, RHL2 (for RH50B & RH65B)

Empire Log Set for RH50B & RH65B
$109.00